Characterization of Chlorolignins in Bleached Kraft Pulp Mill Effluents Using Elemental Analysis and Fingerprinting by CuO Oxidation And Hplc

1994

Abstract Elemental analyses and chemical degradation techniques were applied to characterize lignin compounds in different stages of the chlorine bleaching process and in total mill effluent. Ultrafiltration was used for separation of chlorolignins into three nominal molecular weight fractions. Alkaline CuO oxidation products were analyzed by HPLC with diode array detection. Major compounds were identified by reference to authentic compounds. For comparison, native lignins (MWL), kraft lignins, and humic substances were studied as well. The oxygen, carbon and organic chlorine contents were closely similar in the various mill samples and their fractions. In all mill samples, vanillin and 6-c…

Health Toxicology and MutagenesisUltrafiltrationSoil Sciencechemistry.chemical_element010501 environmental sciencescomplex mixtures01 natural sciencesAnalytical Chemistrychemistry.chemical_compoundChlorineEnvironmental ChemistryLigninWaste Management and DisposalChemical decomposition0105 earth and related environmental sciencesWater Science and TechnologyChromatographyVanillin010401 analytical chemistrytechnology industry and agriculturePublic Health Environmental and Occupational Healthfood and beveragesPollution6. Clean water0104 chemical sciencesKraft processchemistryElemental analysisKraft paperInternational Journal of Environmental Analytical Chemistry
researchProduct

Wireless ECG and cardiac monitoring systems: State of the art, available commercial devices and useful electronic components

2021

Abstract Wireless ElectroCardioGram (ECG) systems are employed in manifold application fields: tele-monitoring, sport applications, support to ageing people at home, fetal ECG, wearable devices and ambulatory monitoring. The presence of cables often hinders user’s free movements, alongside clinicians’ routine operations. Therefore, wireless ECG systems are desirable. This paper aims at reviewing the solutions described in the literature, besides commercially available devices and electronic components useful to setup laboratory prototypes. Several systems have been developed, different in terms of the adopted technology; when approaching the development of a wireless ECG system, some import…

Computer scienceElectrodemedicine.medical_treatmentWireless communication02 engineering and technology01 natural sciencesMultiplexerlaw.inventionBluetoothElectrocardiographyData acquisitionlawSettore ING-IND/12 - Misure Meccaniche E Termiche0202 electrical engineering electronic engineering information engineeringmedicineMiniaturizationWirelessElectrical and Electronic EngineeringInstrumentationWearable technologyECGbusiness.industryApplied Mathematics020208 electrical & electronic engineering010401 analytical chemistryCondensed Matter Physics0104 chemical sciencesvisual_artElectronic componentvisual_art.visual_art_mediumWireless ECGCardiac monitoringbusinessBiomedical engineeringComputer hardwareMeasurement
researchProduct

Impact of Destroying the Structure of Model Gels on Volatile Release

2007

International audience; The release of a strawberry aroma from different composite gels taken as models of fruit preparations and from a sucrose solution was investigated. The composition of the model systems differed with regard to the gelling agent, either pectin or carrageenan, and to the rigidity of the gel. With the use of atmospheric pressure chemical ionization−mass spectrometry, the release profiles of the aroma compounds were determined under stirring. At the same time, purge and trap measurements were performed to determine the release profiles of the aroma compounds without stirring. The comparison of the patterns obtained using these two complementary methods made it possible to…

Sucrosefood.ingredientPectinflavor profileMass spectrometry01 natural sciencesFragariachemistry.chemical_compound0404 agricultural biotechnologyfood[CHIM.ANAL]Chemical Sciences/Analytical chemistryrelease rateAroma compound[CHIM]Chemical SciencesstructureCaproatesFlavorAromaChromatographyVolatilisationbiology010401 analytical chemistrydiffusionfood and beveragesAPCI-MS04 agricultural and veterinary sciencesGeneral Chemistrybiology.organism_classification040401 food science0104 chemical sciencesCarrageenanSolutionsAroma release[CHIM.POLY]Chemical Sciences/PolymerschemistryModels ChemicalFruitOdorantsVolatilizationGeneral Agricultural and Biological SciencesVolatility (chemistry)Gels
researchProduct

Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

2017

A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …

Resolution (mass spectrometry)Capillary actionAnalytical chemistry02 engineering and technologycapillary LC01 natural scienceslaw.inventionlcsh:ChemistrylawLiquid chromatography–mass spectrometrySample preparationSolid phase extractionon-line solid phase extractionFiltrationOriginal ResearchDetection limitChromatographyChemistry010401 analytical chemistryGeneral ChemistryRepeatability021001 nanoscience & nanotechnology0104 chemical sciencespharmaceutical productsChemistrylcsh:QD1-999column switchinglarge volume injection0210 nano-technologyFrontiers in Chemistry
researchProduct

Ion mobility spectrometry as a fast analytical tool in benzalkonium chloride homologs determination.

2017

Abstract A novel procedure is proposed for the determination by ion mobility spectrometry (IMS) of C 12 , C 14 and C 16 benzalkonium chloride (BAC) homologs. The proposed method requires minimum sample treatment and the measurement was made in less than one minute. A high sensitivity was obtained for BAC determination by IMS with limit of detection values from 37 to 69 µg L −1 . Accuracy of the proposed methodology was evaluated through the analysis of aqueous and alcoholic samples spiked with BAC at concentration levels from 0.002% to 20% (w/v), providing recovery values from 91% to 104%. BAC was determined in sanitary alcohols, nasal sprays, postharvest products, algaecides, and treated s…

Detection limitAqueous solutionChromatographyChemistryIon-mobility spectrometry010401 analytical chemistryAnalytical chemistry010501 environmental sciences01 natural sciencesSwimming pool water0104 chemical sciencesAnalytical ChemistryBenzalkonium chloridemedicineBAC determination0105 earth and related environmental sciencesmedicine.drugTalanta
researchProduct

Fungi and Bacteria in Indoor Cultural Heritage Environments: Microbial-related Risks for Artworks and Human Health

2016

Cultural heritage constitutive materials can provide excellent substrates for microbial colonization, highly influenced by thermo-hygrometric parameters. In cultural heritage-related environments, a detrimental microbial load may be present both on manufacts surface and in the aerosol. In this study, bacterial and fungal colonisation has been investigated in three Sicilian confined environments (archive, cave and hypogea), each with peculiar structures and different thermo-hygrometric parameters. Particular attention has been paid to microorganisms able to induce artifacts biodeterioration and to release biological particles in the aerosol (spores, cellular debrides, toxins and allergens) p…

EcologyEcologyMicroorganismfungi010401 analytical chemistryBiological particles010501 environmental sciencesEnvironmental Science (miscellaneous)BiologyIntegrated approachbiology.organism_classification01 natural sciencesPollution0104 chemical sciencesCultural heritageColonisationHuman healthSymbiosisAerobiology Bioaerosol Biodeterioration Healthcare Preventive ConservationSettore BIO/03 - Botanica Ambientale E ApplicataBacteria0105 earth and related environmental sciencesNature and Landscape Conservation
researchProduct

Estimation of Solute-Stationary Phase and Solute-Mobile Phase Interactions in the Presence of Ionic Liquids

2019

The presence of free silanols on alkyl-bonded reversed-phase stationary phases is responsible for broad and asymmetrical peaks when basic drugs are chromatographed with conventional octadecylsilane (C18) columns due to ionic interactions. In the last few years, ionic liquids (ILs) have attracted attention to reduce this undesirable silanol activity. ILs should be considered as dual modifiers (with a cationic and anionic character), which means that both cations and anions are able to adsorb on the stationary phase, creating a positively or negatively charged layer, depending on the relative adsorption. The accessibility of basic compounds to the silanols is prevented by both the IL cation a…

Inorganic chemistryRPLCIonic bondingFiltration and Separation01 natural sciencesAnalytical ChemistryIonlcsh:Chemistryionic liquidschemistry.chemical_compoundAdsorptionPhase (matter)Triethylaminepeak shape010405 organic chemistry010401 analytical chemistryCationic polymerizationchemical equilibrialcsh:QC1-9990104 chemical sciencesSilanolbasic drugslcsh:QD1-999chemistryIonic liquidlcsh:PhysicsSeparations
researchProduct

Highly sensitive olfactory biosensors for the detection of volatile organic compounds by surface plasmon resonance imaging

2018

International audience; Nowadays, monitoring of volatile organic compounds (VOCs) is very important in various domains. In this work, we aimed to develop sensitive olfactory biosensors using odorant binding proteins (OBPs) as sensing materials. Three rat OBP3 derivatives with customized binding properties were designed and immobilized on the same chip for the detection of VOCs in solution by surface plasmon resonance imaging (SPRi). We demonstrated that the proteins kept their binding properties after the immobilization under optimized conditions. The obtained olfactory biosensors exhibited very low limits of detection in both concentration (200pM of beta-ionone) and in molecular weight of …

volatile organic compoundConformational change[SDV.BIO]Life Sciences [q-bio]/BiotechnologyOdorant bindingBiomedical EngineeringBiophysicsBiosensing Techniques02 engineering and technologyReceptors Odorant01 natural sciencesHexanal[SPI]Engineering Sciences [physics]chemistry.chemical_compoundElectrochemistryAnimalsVolatile organic compoundComputingMilieux_MISCELLANEOUSDetection limitchemistry.chemical_classificationVolatile Organic CompoundsChromatographyChemistry010401 analytical chemistryGeneral MedicineRepeatabilitySurface Plasmon Resonance021001 nanoscience & nanotechnologyRats0104 chemical sciencesSmellsurface plasmon resonance imagingofactory biosensor0210 nano-technologySelectivityBiosensorodorant binding proteinsBiotechnologyBiosensors and Bioelectronics
researchProduct

Status of the project TRAPSENSOR: Performance of the laser-desorption ion source

2013

Abstract Penning traps provide mass measurements on atomic nuclei with the highest accuracy and sensitivity. Depending on the experiment and on the physics goal, a relative mass uncertainty varying from 10 −7 to below 10 −11 is required. Regarding sensitivity, the use of only one ion for the measurement is crucial, either to perform mass measurements on superheavy elements (SHE), or to reach δ m / m ≈ 10 - 11 in order to contribute to the direct determination of the mass of the electron-antineutrino with accurate mass measurements on specific nuclei. This has motivated the development of a new technique called Quantum Sensor based on a laser-cooled ion stored in a Penning trap, to perform m…

Nuclear and High Energy PhysicsChemistry010401 analytical chemistryQuantum sensorMass spectrometryPenning trap7. Clean energy01 natural sciencesIon source0104 chemical sciencesComputational physicsIonSecondary ion mass spectrometry0103 physical sciencesIon trapTime-of-flight mass spectrometryAtomic physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Solid-state electrochemical characterization of emissions and authorities producing Roman brass coins

2020

[EN] The voltammetry of immobilized particles (VIMP) is applied to describe the solid state electrochemistry of brass. This methodology, which involves sampling at the nanogram level, is applied to discriminate mints/authorities producing different Roman monetary emissions covering since the Republic (88 BCE) to Domitianus (55-96 CE) Upon attachment to graphite electrodes in contact with aqueous acetate buffer at pH 4.75, well defined voltarnmetric responses were obtained centered on Cu- and Zn-localized signals whose intensity can be correlated to EMP data, being sensitive to the contents of Zn (15-30 wt.%) and Sn (0.01-1.1 wt.%). Voltammetric data, combined with ATR-FTIR and FIB-PESEM/EDS…

Materials scienceSolid-stateAnalytical chemistry02 engineering and technologyElectrochemistry01 natural sciencesArchaeometryAnalytical Chemistryarchaeometry; orichalcum; Roman coins; voltammetryBrassVoltammetrySpectroscopyGraphite electrodevoltammetryAqueous solutionRoman coins010401 analytical chemistryOrichalcum021001 nanoscience & nanotechnology0104 chemical sciencesCharacterization (materials science)Yield (chemistry)visual_artPINTURAvisual_art.visual_art_mediumVoltammetryarchaeometryorichalcum0210 nano-technology
researchProduct